Chủ Nhật, 27 tháng 4, 2014

CM-780N-EG Atago | In-line Brix-Monitor CM-780N-EG | Atago Vietnam

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miễu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Tell : 0915.980.479
        0162.999.888.7
Email : vinhmv.pitesco@gmail.com
Website: www.pitesvietnam.com
              www.sensor-encoder.com

In-line Brix-Monitor

These in-line models can be incorporated in piping of manufacturing plants, liquid mixing devices, and washing apparatuses to continuously measure the concentration of various liquids. 
They are suitable for use in the control of mixing, concentration, fermentation, and control of the concentration of water-based or alkali-based detergent, etc.

In-line Brix-Monitor CM-780N

 Calibration with water Digital display AC outlet (AC100 to 240V) Automatic Temperature Compensation High temperature samples Can be connected to a recorder RS-232C Interface In-line measurement Continuous measurement
This refractometer is a compact in-line model which can be incorporated in piping of manufacturing plants, or a liquid mixing apparatus, or a washing apparatus to continuously measure concentration (Sugar content : Brix) and is suitable for use in control of mixing or concentrating processes at food manufacturing plants, in control of fermentation equipment (alcohol, soysouce, etc.), in control of concentration of water-based or alkali-based detergent, etc.

Specifications

ModelCM-780N
Cat.No.3561
ScaleBrix [*1] 
(Automatic Temperature Compensation according to the sample liquid)
Temperature
Measurement RangeBrix : 0.0 to 78.0%
Temperature : 5 to 100°C
ResolutionBrix : 0.1%
Temperature : 1°C
Measurement AccuracyBrix : ±0.2%
Temperature : ±1°C
Temperature compensation range5 to 100°C (Automatic Temperature Compensation)
Ambient Temperature5 to 40°C
IndicationBrix : -2.0 to 78.5%
Temperature : 0 to 130°C
Output(1) Recorder output : DC 4 to 20mA
(2) RS-232C output
MaterialsPrism : Sapphire
Prism stage : SUS316
Power SupplyDC24V
International Protection ClassIP64 Dust-tight and Protected against splashing water.
Included AccessoriesPower input cable (1m) [*2]
Dimensions & Weight16×17×11cm, 1.8kg 
(Main Unit only)
Power consumption3VA
[*1] : Contact ATAGO if you are interested in using the CM-780N to measure other types of solution.
[*2] : The cable can be ordered to a custom length of up to 5m.

Options

· Hose connector 12mmΦ : RE-6645
· Compression fitting 10mmΦ : RE-6651
· Stand (Stand for mounting the CM-780N and the AC adapter) : RE-8607
· AC adapter AD-32 (AC100V) : Cat.No.3527
· AC adapter AD-33 (AC110 to 120V) : Cat.No.3528
· AC adapter AD-34 (AC220 to 240V) : Cat.No.3529
* Calibration Certificate : Contact an ATAGO representative for details.
See here for other accessories.
TOP
CM-780N
Enlargement
Product Comparison
Quantity  Request Quotation
SUS316L customizable PROFIBUS compatible VARIVENT compatible
Catalog Download1.11MB

In-line Brix-Monitor CM-780N-Plus

 Calibration with water Digital display AC outlet (AC100 to 240V) Automatic Temperature Compensation High temperature samples Can be connected to a recorder RS-232C Interface In-line measurement Continuous measurement
This model features a higher accuracy level than the CM-780N. It measures from 0.0 to 60.0% Brix at the accuracy of ±0.1% within a sample temperature of 5 to 60℃.

Specifications

ModelCM-780N-Plus
Cat.No.3562
ScaleBrix [*1] 
(Automatic Temperature Compensation according to the sample liquid)
Temperature
Measurement RangeBrix : 0.0 to 78.0%
Temperature : 5 to 100°C
ResolutionBrix : 0.1%
Temperature : 1°C
Measurement AccuracyBrix : ±0.1% (0.0 to 60.0% at 5 to 60℃) 
Brix : ±0.2% (For ranges other than above)
Temperature : ±1°C
Temperature compensation range5 to 100°C (Automatic Temperature Compensation)
Ambient TemperatureTemperature 5 to 40°C
IndicationBrix : -2.0 to 78.5%
Temperature : 0 to 130°C
Output(1) Recorder output : DC 4 to 20mA
(2) RS-232C output
MaterialsPrism : Sapphire
Prism stage : SUS316
Power SupplyDC24V
International Protection ClassIP64 Dust-tight and Protected against splashing water.
Included AccessoriesPower input cable (1m) [*2]
Dimensions & Weight16×17×11cm, 1.8kg 
(Main Unit only)
Power consumption3VA
[*1] : Contact ATAGO if you are interested in using the CM-780N-Plus to measure other types of solution. 
[*2] : The cable can be ordered to a custom length of up to 5m.

Options

· Hose connector 12mmΦ : RE-6645
· Compression fitting 10mmΦ : RE-6651
· Stand (Stand for mounting the CM-780N and the AC adapter) : RE-8607
· AC adapter AD-32 (AC100V) : Cat.No.3527
· AC adapter AD-33 (AC110 to 120V) : Cat.No.3528
· AC adapter AD-34 (AC220 to 240V) : Cat.No.3529
* Calibration Certificate : Contact an ATAGO representative for details.
See here for other accessories.
TOP
CM-780N-Plus
Enlargement
Product Comparison
Quantity  Request Quotation
SUS316L customizable PROFIBUS compatible VARIVENT compatible
Catalog Download1.11MB

In-line Brix-Monitor CM-780N-EG

 Calibration with water Digital display AC outlet (AC100 to 240V) Automatic Temperature Compensation High temperature samples Can be connected to a recorder RS-232C Interface In-line measurement Continuous measurement
The CM-780N-EG is specially designed for in-line concentration measurements of ethylene glycol solutions used as coolants, brine, anti-freeze, and de-icing fluids. It also has a secondary scale for the freezing point.

Specifications

ModelCM-780N-EG
Cat.No.3544
ScaleE.G. 
(Automatic Temperature Compensation according to the sample liquid)
Temperature
Measurement RangeE.G. : 0.0 to 90.0%
Freezing point : 0 to -50°C
Temperature : 5 to 100°C
ResolutionE.G. : 0.1%
Freezing point : 1°C
Temperature : 1°C
Measurement AccuracyE.G. : ±0.4%
Freezing point : ±1°C
Temperature : ±1°C
Temperature compensation range5 to 100°C
(Automatic Temperature Compensation)
Ambient Temperature5 to 40°C
IndicationE.G. : -2.0 to 105.5%
Freezing point : 0 to -50°C
Temperature : 0 to 130°C
OutputRS-232C ,DC 4 to 20mA
MaterialsPrism : Sapphire
Prism stage : SUS316
Power SupplyDC24V
International Protection ClassIP64
Dust-tight and Protected against splashing water.
Included AccessoriesPower input cable (1m) [*1]
Dimensions & Weight16×17×11cm, 1.8kg
(Main Unit only)
[*1] : The cable can be ordered to a custom length of up to 5m.

Options

· Hose connector 12mmΦ : RE-6645
· Compression fitting 10mmΦ : RE-6651
· Stand (Stand for mounting the CM-780N and the AC adapter) : RE-8607
· AC adapter AD-32 (AC100V) : Cat.No.3527
· AC adapter AD-33 (AC110 to 120V) : Cat.No.3528
· AC adapter AD-34 (AC220 to 240V) : Cat.No.3529
* Calibration Certificate : Contact an ATAGO representative for details.
See here for other accessories.
TOP
CM-780N-EG
Enlargement
Product Comparison
Quantity  Request Quotation
SUS316L customizable PROFIBUS compatible VARIVENT compatible

In-line Salinity Monitor CM-780N-SW

 Calibration with water Digital display AC outlet (AC100 to 240V) Automatic Temperature Compensation High temperature samples Can be connected to a recorder RS-232C Interface In-line measurement Continuous measurement
This is an in-line refractometer for concentrations of sodium chloride in water (0.0-28.0%).
It is built to the same specifications as the original CM-780N with the Brix scale.

Specifications

ModelCM-780N-SW
Cat.No.3543
ScaleSalinity (Automatic Temperature Compensation according to the sample liquid)
Temperature
Measurement RangeSalinity : 0.0 to 28.0%
Temperature : 5 to 100°C
ResolutionSalinity : 0.1%
Temperature : 1°C
Measurement AccuracySalinity : ±0.2%
Temperature : ±1°C
Temperature compensation range5 to 100°C (Automatic Temperature Compensation)
Ambient Temperature5 to 40°C
IndicationSalinity : -2.0 to 28.5%
Temperature : -7 to 130°C
Output(1) Recorder output : DC 4 to 20mA
(2) RS-232C output
MaterialsPrism : Sapphire
Prism stage : SUS316
Power SupplyDC24V
International Protection ClassIP64 Dust-tight and Protected against splashing water.
Included AccessoriesPower input cable (1m) [*1]
Dimensions & Weight16×17×11cm, 1.8kg 
(Main Unit only)
Power consumption3VA
[*1] : The cable can be ordered to a custom length of up to 5m.

Options

· Hose connector 12mmΦ : RE-6645
· Compression fitting 10mmΦ : RE-6651
· Stand (Stand for mounting the CM-780N and the AC adapter) : RE-8607
· AC adapter AD-32 (AC100V) : Cat.No.3527
· AC adapter AD-33 (AC110 to 120V) : Cat.No.3528
· AC adapter AD-34 (AC220 to 240V) : Cat.No.3529
* Calibration Certificate : Contact an ATAGO representative for details.
See here for other accessories.
TOP
CM-780N-SW
Enlargement
Product Comparison
Quantity  Request Quotation
SUS316L customizable PROFIBUS compatible VARIVENT compatible

In-line Brix-Monitor CM-800α

 Calibration with water Digital display AC outlet (AC100 to 240V) Automatic Temperature Compensation High temperature samples Can be connected to a recorder RS-232C Interface In-line measurement Continuous measurement
This new addition to the CM series is compatible with the PRM-100α fittings.
Fittings are available in a wide variety of shapes and sizes.
The accuracy is ±0.1% across the entire range of 0-80% Brix.

Specifications

ModelCM-800α
Cat.No.3564
ScaleBrix [*1]
(Automatic Temperature Compensation according to the sample liquid)
Temperature
Measurement RangeBrix : 0.0 to 80.0%
Temperature : 5 to 100°C
ResolutionBrix : 0.01 or 0.1% 
(with an option to display measurements between 0.00 and 9.99% to the 2nd decimal place)
Temperature : 1°C
Measurement AccuracyBrix : ±0.1%
Temperature : ±1°C
Temperature compensation range5 to 100°C (Automatic Temperature Compensation)
Ambient Temperature5 to 40°C
IndicationBrix : -2.0 to 80.5%
Temperature : 0 to 130°C
Output(1) Recorder output : DC 4 to 20mA
(2) RS-232C output
MaterialsPrism : Sapphire
Prism stage : SUS316
Power SupplyDC24V
International Protection ClassIP64 Dust-tight and Protected against splashing water.
Included AccessoriesPower input cable (1m) [*2]
Dimensions & Weight16×17×11cm, 2.4kg
(Main Unit only)
Power consumption24VA
[*1] : Contact ATAGO if you are interested in using the CM-800α to measure other types of solution.
[*2] : The cable can be ordered to a custom length of up to 5m.

Options

* Calibration Certificate : Contact an ATAGO representative for details.
See here for fitting options.
TOP
CM-800α
Enlargement
Product Comparison
Quantity  Request Quotation
SUS316L customizable PROFIBUS compatible VARIVENT compatible
Catalog Download533KB

In-line Brix-Monitor CM-BASE(A)

 Calibration with water Digital display AC outlet (AC100 to 240V) Automatic Temperature Compensation Can be connected to a recorder RS-232C Interface In-line measurement Continuous measurement
Easy operation with only one cable for power supply and data output.Optimized for automation of real-time concentration monitoring.
The CM-BASE (A) transmits data via 4-20mA signals.

Specifications

ModelCM-BASE(A)
Cat.No.3593
ScaleBrix
Measurement RangeBrix : 0.0 to 33.0%
ResolutionBrix : 0.1%
Measurement AccuracyBrix : ±0.5%
Temperature compensation range0 to 50°C
( Automatic Temperature Compensation)
Ambient Temperature10 to 40°C
IndicationBrix : -2.0 to 33.5%
OutputDC4 to 20mA
International Protection ClassIP64
Dust-tight and Protected against splashing water.
Included AccessoriesSignal cable
(DC24V input, Recorder output)
2m [*1]
Dimensions & Weight90×90×59mm, 670g (Main unit only)
[*1] : The cable can be ordered to a custom length of up to 100m.

Options

· Hose Connector 12mmΦ : RE-67580
· Compression Fitting 10mmφ : RE-67581
TOP
CM-BASE(A)
Enlargement
Product Comparison
Quantity  Request Quotation
SUS316L customizable PROFIBUS compatible VARIVENT compatible
Catalog Download172KB

In-line Brix-Monitor CM-BASE(D)

 Calibration with water Digital display AC outlet (AC100 to 240V) Automatic Temperature Compensation Can be connected to a recorder RS-232C Interface In-line measurement Continuous measurement
Easy operation with only one cable for power supply and data output.Optimized for automation of real-time concentration monitoring.
The CM-BASE (D) transmits data to a computer via RS-232C.

Specifications

ModelCM-BASE(D)
Cat.No.3594
ScaleBrix
Measurement RangeBrix : 0.0 to 33.0%
ResolutionBrix : 0.1%
Measurement AccuracyBrix : ±0.5%
Temperature compensation range0 to 50°C
( Automatic Temperature Compensation)
Ambient Temperature10 to 40°C
IndicationBrix : -2.0 to 33.5%
OutputRS-232C
Communications parametersBaud rate : 2400bps
Partity : Even
Data length : 7bit
Stop bit : 1bit
Transmit dataaa.a,bb.b(Brix, Temperature)
(Example) Brix =19.5%,Temperature = 20.3°C ⇒ "19.5,20.3"
International Protection ClassIP64
Dust-tight and Protected against splashing water.
Included AccessoriesSignal cable
(DC24V input, RS-232C output) 
2m [*1]
Dimensions & Weight90×90×59mm, 670g (Main unit only)
[*1] : The cable can be ordered to a custom length of up to 15m.

Options

· Hose Connector 12mmΦ : RE-67580
· Compression Fitting 10mmφ : RE-67581